Water temperature measurements from Durleigh Reservoir 2018
This dataset contains water temperature measurements at 2 different locations in Durleigh Reservoir in Somerset, England. Water temperatures were measured using RBR SoloT thermistors (measured in °C) and HOBO TidbiT v2 loggers (measured in °F). The dataset consists of water temperature measurements from 2 locations at Durleigh reservoir between 22 February 2018 and 5 October 2018. Measurements were taken at 10 minute intervals. Full details about this dataset can be found at https://doi.org/10.5285/25d34c83-e939-40fd-aa16-6962efb4c731
dataset
https://data-package.ceh.ac.uk/data/25d34c83-e939-40fd-aa16-6962efb4c731
name: Download the data
description: Download a copy of this data
function: download
https://data-package.ceh.ac.uk/sd/25d34c83-e939-40fd-aa16-6962efb4c731.zip
name: Supporting information
description: Supporting information available to assist in re-use of this dataset
function: information
https://catalogue.ceh.ac.uk/id/25d34c83-e939-40fd-aa16-6962efb4c731
doi:
eng
inlandWaters
environment
Environmental Monitoring Facilities
publication
2008-06-01
-3.056
-3.037
51.125
51.118
2018-02-22
2018-10-05
publication
2020-05-05
The first site, labelled location 2, is closer to the artificial mixing devices (surface mixers) installed in the reservoir (60 m away) and deeper, with a water depth of 6 m when on deployment (latitude: 51.1210, longitude: -3.0403). The second site, labelled location 3, is farther away from the artificial mixing devices installed in the reservoir (435 m away) and in a shallower region, with a water depth of 4 m on deployment (latitude: 51.1215, longitude: -3.0445). At location 2, RBR SoloT thermistors (measured in °C) were positioned at 1 m intervals from the surface (0 m depth) to the bottom of the water column (6 m). However, in the dataset temperature measurements from thermistors positioned at 1 m, 2 m, and 3 m are missing due to corrupted files. At location 3, HOBO TidbiT v2 loggers (measured in °F) were positioned at 1 m intervals from the surface (0 m depth) to the bottom of the water column (4 m depth). All water temperature measurements were taken at 10-minute intervals. Both temperature chains consisted of a buoy (A2 size) attached to a 10 kg weight using a rope, and the thermistors were attached onto the rope. All thermistors were deployed between 22 February and 5 October 2018.
publication
2010-12-08
Comma-separated values (CSV)
© University of Bath
If you reuse this data, you should cite: Slavin, E.I., Wain, D.J. (2020). Water temperature measurements from Durleigh Reservoir 2018. NERC Environmental Information Data Centre https://doi.org/10.5285/25d34c83-e939-40fd-aa16-6962efb4c731
University of Bath
author
7 Lakes Alliance
author
University of Bath
pointOfContact
NERC EDS Environmental Information Data Centre
custodian
NERC Environmental Information Data Centre
publisher
Environmental Information Data Centre
Lancaster Environment Centre, Library Avenue, Bailrigg
Lancaster
LA1 4AP
UK
pointOfContact
2022-05-18T12:37:49